Recalibration can reset one of the triggers and render it unusable. #6
Reference in New Issue
Block a user
Delete Branch "%!s()"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Originally created by @arcanechocolate on GitHub (Jun 23, 2024).
I recalibrated using the web-app several times with no issue. This last time my R2 completely stopped working after doing the calibration.
Tried a variety of things to no avail, so in the end I went back to the old python script and used the experimental R2/L2 calibration (first time using it) and doing that brought it back "online".
Edit: Apparently it didn't fix it. I was confused. What happens is that my Right Analog Stick, besides interpreting both axis correctly, also assumes the function of R2 when pressed to the Left. So RX,0 = R2,0, and RX,-1 = R2,1.
@arcanechocolate commented on GitHub (Jun 23, 2024):
Not caused by the application. It's caused by a bad contact or something else hardware related. My apologies.